Short answer: in Maryland, a buried home heating oil tank that's no longer used must be removed or closed in place, and the work has to be done under the on-site supervision of an MDE-certified UST technician or remover. So start with certified firms and check the name with MDE. Good places to start: GreenTRAX for residential tanks around a sale (and Annapolis), Tankmasters to test first, JB Tank for removal plus a new tank, Maryland Tank & Environmental, RCFS and Advanced Environmental Concepts as officially listed removers that also handle spills, Datanet Engineering for larger regulated tanks, and Miller Environmental Group (listed as ACE Environmental) for emergencies.

By the Tank Removers Editorial Team · Updated October 29, 2026

Two workers in hard hats and safety vests inspecting a large excavated steel storage tank at an urban cleanup site
Inspecting an excavated tank during a leaking-UST removal in Washington, D.C., just over the Maryland line (2010). Home heating oil tanks are much smaller, but the closure steps (empty, clean, remove, sample the soil) are the same idea. Photo: U.S. EPA, public domain, via Wikimedia Commons.

How we chose

Maryland is stricter about who does the work than its neighbors. Pennsylvania doesn't regulate most home heating oil tanks at the state level, and Rhode Island exempts them from most of its rules. MDE also exempts residential tanks of 1,100 gallons or less from most of its oil control regulations while they're in use, but once a tank stops being used it has to be removed or closed in place, and the closure has to be supervised on site by an MDE-certified UST System Technician or Remover. That gave us a clean starting point: official lists of certified firms. We started from Baltimore County's list of contractors who reported holding MDE certification to remove residential tanks (revised September 2024) and MDE's spill contractors list (revised March 2025), then read each firm's own website where one loaded. We looked for firms that meet these criteria:

  • Appears on an official list (Baltimore County’s residential UST remover list or MDE’s spill contractors list), or names its MDE certification on its own site
  • Works in Maryland and says which counties it covers
  • Handles residential buried tanks, or says clearly what kind of work it focuses on
  • Can sample soil, or can deal with a release if one turns up
  • Says what it handles for you: Miss Utility, local permits, inspections, closure paperwork

Nobody paid for placement. We list our own site first because it is a different kind of option (a matching service), and we label it. Baltimore County itself says its list is based on what contractors reported and makes no claim about completeness or quality, and MDE says the same about its spill list. Being on a list is not an endorsement. We didn't verify individual certifications or insurance; MDE's certification search is the place to do that before you sign.

Comparison table

CompanyService areaListings and stated credentialsBest forSource
Tank Removers (this is our site)Maryland (matching service)Free quote matching with participating local contractors; we do not perform removals ourselvesGetting several written quotes from one requestHow it works
GreenTRAX, Inc.Anne Arundel (including the City of Annapolis), Baltimore County and City, Howard, Montgomery, Prince George’s, Harford and Calvert; based in MillersvilleSays it is a second-generation tank contractor with 25+ years in heating oil tanks; on Baltimore County’s residential UST remover list (also marked MDE-certified for tightness testing)Residential buried tanks tied to a home sale, especially in Annapoliscompany website
Tankmasters, Inc.Statewide, with an emphasis on Baltimore, Howard and Montgomery Counties; based in SparksLists State of Maryland certified installer, certified remover and certified upgrade/repair; on Baltimore County’s residential UST remover list (also marked MDE-certified for tightness testing)Testing a tank before deciding, then removal or closure in place by the same firmcompany website
JB Tank LLCMid-Atlantic; based in White Hall (northern Baltimore County)Says it has 30+ years of experience and is UST certified and STI/SP001 certified; on Baltimore County’s residential UST remover listRemoving a buried tank and installing an aboveground replacement in one jobcompany website
Maryland Tank & Environmental, LLCBased in Tracys Landing (southern Anne Arundel County)On Baltimore County’s residential UST remover list and on MDE’s spill contractors list for both underground and surface spills (full service)Southern Anne Arundel and Calvert-area homeowners, including tanks that have leakedMDE spill contractors list
RCFS, Inc.Based in Jarrettsville (Harford County)On Baltimore County’s residential UST remover list and on MDE’s spill contractors list for both underground and surface spillsHarford County and northern Baltimore County homeownersBaltimore County contractor list
Advanced Environmental Concepts, Inc.Based in Havre de Grace (Harford County)On Baltimore County’s residential UST remover list and on MDE’s spill contractors list for both underground and surface spillsLeaks and contaminated soil in Harford and Cecil-area jobsMDE spill contractors list
Datanet Engineering, Inc.Based in Owings Mills; Maryland and Washington, DCFounded in 1983; says its personnel hold MDE UST Installer/Remover/Inspector and DC DOEE UST Technician certifications; on Baltimore County’s list (also marked for tightness testing) and MDE’s spill listTanks over 1,100 gallons, multifamily or mixed-use buildings and anything MDE regulatescompany website
Miller Environmental Group (listed as ACE Environmental)Baltimore; 24-hour emergency responseBaltimore County’s remover list and MDE’s spill list name ACE Environmental at 4420 East Eager Street; that company’s web address now shows Miller Environmental Group at the same address and phoneAn active leak, oil in a basement or sump, or a spill during removalcompany website

Independent firms are listed in no particular order. No prices, ratings or review counts are shown on purpose. Listings checked October 29, 2026.

Tank Removers (this is our site)

Maryland (matching service) · Best for: Getting several written quotes from one request

Disclosure: Tank Removers is our own website. We are not a removal contractor. You describe the tank once (buried or basement, size if you know it, your county), and we connect you with participating local pros so you can compare written scopes side by side. Only contractors in our network appear, so the independent firms below are worth calling directly too. In Maryland, the person in charge on site has to hold an MDE certification, so whoever you hire, ask for the certified technician’s or remover’s name and check it with MDE’s certification search before work starts.

Source: How it works

GreenTRAX, Inc.

Anne Arundel (including the City of Annapolis), Baltimore County and City, Howard, Montgomery, Prince George’s, Harford and Calvert; based in Millersville · Best for: Residential buried tanks tied to a home sale, especially in Annapolis

GreenTRAX says it specializes in residential oil tank removals and that most home tanks it sees run from 275 to 1,000 gallons, with 550 the most common. Its site lists the steps it handles: calling Miss Utility, pulling permits, scheduling inspectors, clean backfill, soil samples, well-water samples and a closure report, plus follow-up work if MDE asks for more. It also says the City of Annapolis runs its own tank permit process and that its family has done more tank work there than any other single company in the last 20 years (its claim). It works a lot with agents and title companies around settlement. One thing to check: its site says MDE requires a tank to be removed within 180 days of going out of service, while the current text of COMAR 26.10.01.13 sets 30 days from the decision to close a residential heating oil tank. Ask which deadline applies to your tank.

Source: company website

Tankmasters, Inc.

Statewide, with an emphasis on Baltimore, Howard and Montgomery Counties; based in Sparks · Best for: Testing a tank before deciding, then removal or closure in place by the same firm

Tankmasters is run by owner David Thompson, who its site says has worked in the UST business for about 35 years, and it says it began offering licensed testing and removal services in 1996. Its services page lists UST testing, tank installations, removals and abandonments, soil and water testing, and backhoe rental with an operator, for heating oil, gasoline, diesel and waste oil tanks (not propane or septic). The testing side is the useful part for a buyer or seller who doesn’t yet know whether a tank leaked. Its site also says it cements both fill and vent pipes inside and outside the home on closures, which is the kind of detail to ask every bidder about.

Source: company website

JB Tank LLC

Mid-Atlantic; based in White Hall (northern Baltimore County) · Best for: Removing a buried tank and installing an aboveground replacement in one job

JB Tank lists residential tank removal and residential tank installation, including home heating oil tanks, and says it handles site surveys and planning for underground tank removal, excavation, testing, permits and state reporting, and works with the local licensing and permit agencies. That makes it a fit for the common Maryland job where a buried tank comes out and a new aboveground or basement tank goes in so the house keeps oil heat. Ask who on its crew holds the MDE certification for your job and what paperwork you get at the end.

Source: company website

Maryland Tank & Environmental, LLC

Based in Tracys Landing (southern Anne Arundel County) · Best for: Southern Anne Arundel and Calvert-area homeowners, including tanks that have leaked

Maryland Tank & Environmental appears on two official lists: Baltimore County’s list of contractors who reported holding MDE certification to remove residential USTs, and the MDE Oil Control Program’s spill contractors list, where it is marked full service for both underground and surface oil spills. Its own website didn’t load when we checked on October 29, 2026, so we’re not repeating claims about its services beyond those lists. The underground-spill listing is the reason to call it if your tank may already have leaked. Ask for the certified remover’s name, the sampling plan and the reporting steps in writing.

Source: MDE spill contractors list

RCFS, Inc.

Based in Jarrettsville (Harford County) · Best for: Harford County and northern Baltimore County homeowners

RCFS appears on Baltimore County’s residential UST remover list and on MDE’s spill contractors list, marked full service for underground and surface spills. We didn’t find a company website for it, so we’re not describing services beyond those official listings. For a northern-county homeowner it’s a local name to include when you collect bids; ask the same questions you would ask any firm on this page.

Source: Baltimore County contractor list

Advanced Environmental Concepts, Inc.

Based in Havre de Grace (Harford County) · Best for: Leaks and contaminated soil in Harford and Cecil-area jobs

Advanced Environmental Concepts is on both official lists we used: Baltimore County’s residential UST remover list and MDE’s spill contractors list, where it is marked full service for underground and surface spills. Its website didn’t load when we checked, so we’re limiting the description to those listings. A contractor that also handles underground spills is the kind you want if soil samples come back dirty and the job turns into a cleanup.

Source: MDE spill contractors list

Datanet Engineering, Inc.

Based in Owings Mills; Maryland and Washington, DC · Best for: Tanks over 1,100 gallons, multifamily or mixed-use buildings and anything MDE regulates

Datanet is a petroleum equipment engineering and construction company rather than a homeowner-focused remover. Its site lists aboveground and underground tank removal, installation, upgrades, testing and inspection, permit application services, MDE and DOEE third-party UST inspections, cathodic protection and tightness testing. That profile matters when your tank is not the typical small home tank: in Maryland, residential and farm USTs over 1,100 gallons are not exempt from MDE’s rules, need to be registered, and need the 30-day closure notice. For a standard 275 to 1,000 gallon home tank, a residential specialist is usually the simpler call.

Source: company website

Miller Environmental Group (listed as ACE Environmental)

Baltimore; 24-hour emergency response · Best for: An active leak, oil in a basement or sump, or a spill during removal

Baltimore County lists ACE Environmental Holdings, LLC as a residential UST remover, and MDE’s spill contractors list includes ACE Environmental Services, LLC at the same East Eager Street address, full service for underground and surface spills. When we opened ACE’s web address on October 29, 2026 it showed Miller Environmental Group, at 4420 East Eager Street with the same phone number, describing 24/7 emergency response, industrial services and waste transportation. Miller Environmental Group also appears separately on MDE’s spill list. This is an emergency-response firm first. If oil is moving, call MDE and a spill contractor like this one; for a routine removal, get bids from the residential firms too.

Source: company website

What Maryland actually requires

Small home tanks: mostly exempt, until you stop using them. MDE's Residential Heating Oil page says USTs of 1,100 gallons or less storing petroleum at a private residence or farm are exempt from most Maryland oil control regulations, but must meet the closure requirements in COMAR 26.10.10 once they are no longer used as a fuel source. MDE's closure fact sheet puts it plainly: once a residential or farm UST is no longer used to store fuel, State law says it must be removed or closed in place. MDE also strongly recommends replacing USTs more than 20 years old.

Who can do the work. The closure has to be done under the on-site supervision and direction of a Maryland-certified UST System Technician or Remover, who must be present and continuously on site. MDE's certification fact sheet adds a Heating Oil Technician certification that covers installing, repairing and closing heating-oil tanks of 2,000 gallons or less. GreenTRAX notes on its site that most plumbing and HVAC companies aren't licensed UST removers, so ask. MDE runs an online search to confirm that a technician or remover is certified.

Notice and permits. For a residential tank of 1,100 gallons or less, MDE says its Oil Control Program does not require prior notice of the closure. Local rules are another matter: the fact sheet says a permit to remove or abandon the tank may be required by your local fire, health or planning department before any digging. In Baltimore County, the contractor files an Underground Storage Tank Removal Notification (form A-26) confirming it is MDE-certified and follows Baltimore County Code 33-7, and an inspection has to be arranged with the county's Ground Water Management section (410-887-2762) before a residential tank under 1,100 gallons comes out. GreenTRAX says the City of Annapolis has its own tank permit process.

Bigger tanks are regulated. Residential and farm USTs over 1,100 gallons are not exempt. They must be registered with MDE's Oil Control Program and follow stricter closure rules, including MDE's 30-day written notification before removal or abandonment. That's where an engineering-led firm earns its keep.

The timeline. COMAR 26.10.01.13 says the closure steps for a residential heating oil tank are to be completed within 30 days of the determination that the tank will be permanently closed, following the PEI RP1700 recommended practice. Basement and aboveground tanks are covered by the same regulation: drain and properly dispose of the oil, remove the tank and its supply lines, and remove the fill and vent pipes or fill them with cement so nobody can deliver oil into them.

Remove or close in place. MDE recommends closing a tank in place only when it sits under a building or removal would endanger a building's structure. Either way, the oil and sludge come out, the piping (including the fill and vent lines) is disconnected and removed, and the tank is cleaned. A tank closed in place is filled to capacity with a solid, inert flowable material such as sand or cement slurry, with no voids, and never with foam or through the fill or vent pipe.

Soil sampling. For a closure in place, MDE's fact sheet calls for soil samples from at least 2 feet below the tank bottom. When a tank is removed and oil-contaminated soil is found, that soil is excavated as far as practicable and post-excavation samples are collected. Samples are analyzed for VOCs (including fuel oxygenates and naphthalene) by EPA Method 8260 and for TPH-DRO and TPH-GRO by EPA Method 8015. Ask every bidder whether their price includes lab samples and who takes them.

If it leaked. You and the contractor must report contamination found during the work to MDE immediately, and no later than 2 hours after discovery: 410-537-3442 during work hours, 1-866-633-4686 after hours. Contaminated soil goes to a permitted landfill or soil treatment facility. A UST System Closure Report goes to MDE if directed or if a release was observed. Keep all records, receipts and photos.

The reimbursement fund is closed. Older pages (including some contractor sites) still mention state money for residential cleanups. MDE says its Residential Heating Oil Tank System Site Rehabilitation Reimbursement Program is no longer active: applications had to be in by July 1, 2024, and expense forms by December 31, 2024.

Questions to ask every Maryland contractor

  1. Who will be the MDE-certified technician or remover on site, and what is the certification number? (Then check it with MDE.)
  2. Is my tank 1,100 gallons or less, and how did you confirm the size? If it's larger, who files MDE's 30-day notice?
  3. What does my county or city require (permit, inspection), and who arranges it?
  4. Will you remove the tank or close it in place, and why? If in place, what fill material?
  5. How many soil samples, analyzed by which methods, and do I get the lab report?
  6. Will you remove the fill and vent pipes and tell my oil company to stop deliveries?
  7. If you find oil, who calls MDE within the 2-hour window, and can your firm handle the cleanup?
  8. What will I get at the end: photos, lab results, disposal receipts, a closure summary for my buyer or lender?

What drives the cost (we don't publish prices)

  • Buried versus basement tank, and the tank's size and depth
  • Access for an excavator, and what has to be protected or restored (row-house yards, driveways, landscaping)
  • Your county or city permit and inspection requirements
  • Fill, vent and supply lines that come out
  • Removal versus closure in place, and the fill material
  • Number of lab samples and whether a written closure summary is included
  • Contaminated soil, if any, and how far it extends

See also: Maryland MDE requirements guide, oil tank removal in Baltimore, oil tank removal in Annapolis, removal vs. abandonment, how to choose a tank company, and our neighboring-state lists for Pennsylvania Delaware and Washington, DC.

Frequently asked questions

Who is the best oil tank removal company in Maryland?

There is no official ranking. On our criteria, GreenTRAX stands out for residential buried tanks around a home sale and for Annapolis permits; Tankmasters for testing first and then removal or closure; JB Tank for removal plus a replacement tank in northern Baltimore County; Maryland Tank & Environmental, RCFS and Advanced Environmental Concepts as officially listed removers that are also on MDE’s spill list; Datanet Engineering for tanks MDE regulates; and Miller Environmental Group (listed as ACE Environmental) for emergencies. Get at least two written scopes and confirm the certified person’s name with MDE.

Do I need an MDE-certified contractor to remove a home heating oil tank in Maryland?

Yes, for an underground tank. MDE’s Residential Heating Oil page says removal must be performed by an MDE-certified technician or remover, and its closure fact sheet says all UST systems, including residential and farm tanks of 1,100 gallons or less, must be closed under the on-site supervision and direction of a Maryland-certified UST System Technician or Remover. A certified Heating Oil Technician can also close heating-oil tanks of 2,000 gallons or less. You can confirm a certification with MDE’s online search.

Do I have to notify MDE before removing a residential oil tank?

Not for a typical home tank of 1,100 gallons or less. MDE says its Oil Control Program does not require prior notice of the closure. Tanks over 1,100 gallons are not exempt and use MDE’s 30-day written notification. Your county or city may still require a permit or inspection; Baltimore County, for example, requires an inspection to be arranged with its Ground Water Management section before a residential tank under 1,100 gallons comes out.

Can I leave my old oil tank in the ground in Maryland?

Not once you stop using it. MDE says that once a residential or farm UST is no longer used to store fuel it must be removed or closed in place, and that closing it in place should be limited to tanks under a building or where removal would endanger a building. A closed-in-place tank must be cleaned and completely filled with a solid, inert flowable material such as sand or cement slurry (foam is not acceptable), with soil samples from at least 2 feet below the tank bottom.

Is there still a Maryland reimbursement fund for oil tank cleanup?

No. MDE says its Residential Heating Oil Tank System Site Rehabilitation Reimbursement Program is no longer active. Under the statute, applications had to be in by July 1, 2024, and expense forms by December 31, 2024. Check your homeowner’s insurance instead, and ask your contractor about it early if a leak is suspected.

What happens if the contractor finds oil in the soil?

You and the contractor must report it to MDE immediately, and no later than 2 hours after discovery: 410-537-3442 during work hours, or 1-866-633-4686 after hours. Contaminated soil is excavated as far as practicable, post-excavation samples are collected and analyzed, the soil goes to an approved disposal site, and MDE may direct a closure report and further cleanup.

How much does oil tank removal cost in Maryland?

We do not publish price ranges. Cost depends on whether the tank is buried or in the basement, its size and depth, access for equipment, your county’s permit or inspection, whether lines and the fill pipe come out, removal versus closure in place, the number of lab samples, and whether any contaminated soil has to go. Compare itemized written quotes that spell out the certified person on site, the sampling plan and the final paperwork.

Get written quotes to compare

Describe your tank once and we'll match you with participating Maryland contractors. Free, no obligation, and every quote is yours to compare.

Get free quotes →